Issue #25173: Replace 'master' with 'parent' in tkinter.messagebox calls.

This associates the message box with the widget and is better for Mac OSX.
Patch by Mark Roseman.
This commit is contained in:
Terry Jan Reedy 2015-09-25 22:22:55 -04:00
parent cbe16aefb8
commit 3be2e54adc
5 changed files with 20 additions and 20 deletions

View file

@ -774,7 +774,7 @@ class ModifiedInterpreter(InteractiveInterpreter):
"Exit?",
"Do you want to exit altogether?",
default="yes",
master=self.tkconsole.text):
parent=self.tkconsole.text):
raise
else:
self.showtraceback()
@ -812,7 +812,7 @@ class ModifiedInterpreter(InteractiveInterpreter):
"Run IDLE with the -n command line switch to start without a "
"subprocess and refer to Help/IDLE Help 'Running without a "
"subprocess' for further details.",
master=self.tkconsole.text)
parent=self.tkconsole.text)
def display_no_subprocess_error(self):
tkMessageBox.showerror(
@ -820,14 +820,14 @@ class ModifiedInterpreter(InteractiveInterpreter):
"IDLE's subprocess didn't make connection. Either IDLE can't "
"start a subprocess or personal firewall software is blocking "
"the connection.",
master=self.tkconsole.text)
parent=self.tkconsole.text)
def display_executing_dialog(self):
tkMessageBox.showerror(
"Already executing",
"The Python Shell window is already executing a command; "
"please wait until it is finished.",
master=self.tkconsole.text)
parent=self.tkconsole.text)
class PyShell(OutputWindow):
@ -931,7 +931,7 @@ class PyShell(OutputWindow):
if self.executing:
tkMessageBox.showerror("Don't debug now",
"You can only toggle the debugger when idle",
master=self.text)
parent=self.text)
self.set_debugger_indicator()
return "break"
else:
@ -1239,7 +1239,7 @@ class PyShell(OutputWindow):
tkMessageBox.showerror("No stack trace",
"There is no stack trace yet.\n"
"(sys.last_traceback is not defined)",
master=self.text)
parent=self.text)
return
from idlelib.StackViewer import StackBrowser
StackBrowser(self.root, self.flist)