mirror of
https://github.com/python/cpython.git
synced 2025-10-18 04:38:07 +00:00

svn+ssh://pythondev@svn.python.org/python/branches/p3yk ................ r55636 | neal.norwitz | 2007-05-29 00:06:39 -0700 (Tue, 29 May 2007) | 149 lines Merged revisions 55506-55635 via svnmerge from svn+ssh://pythondev@svn.python.org/python/trunk ........ r55507 | georg.brandl | 2007-05-22 07:28:17 -0700 (Tue, 22 May 2007) | 2 lines Remove the "panel" module doc file which has been ignored since 1994. ........ r55522 | mark.hammond | 2007-05-22 19:04:28 -0700 (Tue, 22 May 2007) | 4 lines Remove definition of PY_UNICODE_TYPE from pyconfig.h, allowing the definition in unicodeobject.h to be used, giving us the desired wchar_t in place of 'unsigned short'. As discussed on python-dev. ........ r55525 | neal.norwitz | 2007-05-22 23:35:32 -0700 (Tue, 22 May 2007) | 6 lines Add -3 option to the interpreter to warn about features that are deprecated and will be changed/removed in Python 3.0. This patch is mostly from Anthony. I tweaked some format and added a little doc. ........ r55527 | neal.norwitz | 2007-05-22 23:57:35 -0700 (Tue, 22 May 2007) | 1 line Whitespace cleanup ........ r55528 | neal.norwitz | 2007-05-22 23:58:36 -0700 (Tue, 22 May 2007) | 1 line Add a bunch more deprecation warnings for builtins that are going away in 3.0 ........ r55549 | georg.brandl | 2007-05-24 09:49:29 -0700 (Thu, 24 May 2007) | 2 lines shlex.split() now has an optional "posix" parameter. ........ r55550 | georg.brandl | 2007-05-24 10:33:33 -0700 (Thu, 24 May 2007) | 2 lines Fix parameter passing. ........ r55555 | facundo.batista | 2007-05-24 10:50:54 -0700 (Thu, 24 May 2007) | 6 lines Added an optional timeout parameter to urllib.ftpwrapper, with tests (for this and a basic one, because there weren't any). Changed also NEWS, but didn't find documentation for this function, assumed it wasn't public... ........ r55563 | facundo.batista | 2007-05-24 13:01:59 -0700 (Thu, 24 May 2007) | 4 lines Removed the .recv() in the test, is not necessary, and was causing problems that didn't have anything to do with was actually being tested... ........ r55564 | facundo.batista | 2007-05-24 13:51:19 -0700 (Thu, 24 May 2007) | 5 lines Let's see if reading exactly what is written allow this live test to pass (now I know why there were so few tests in ftp, http, etc, :( ). ........ r55567 | facundo.batista | 2007-05-24 20:10:28 -0700 (Thu, 24 May 2007) | 4 lines Trying to make the tests work in Windows and Solaris, everywhere else just works ........ r55568 | facundo.batista | 2007-05-24 20:47:19 -0700 (Thu, 24 May 2007) | 4 lines Fixing stupid error, and introducing a sleep, to see if the other thread is awakened and finish sending data. ........ r55569 | facundo.batista | 2007-05-24 21:20:22 -0700 (Thu, 24 May 2007) | 4 lines Commenting out the tests until find out who can test them in one of the problematic enviroments. ........ r55570 | neal.norwitz | 2007-05-24 22:13:40 -0700 (Thu, 24 May 2007) | 2 lines Get test passing again by commenting out the reference to the test class. ........ r55575 | vinay.sajip | 2007-05-25 00:05:59 -0700 (Fri, 25 May 2007) | 1 line Updated docstring for SysLogHandler (#1720726). ........ r55576 | vinay.sajip | 2007-05-25 00:06:55 -0700 (Fri, 25 May 2007) | 1 line Updated documentation for SysLogHandler (#1720726). ........ r55592 | brett.cannon | 2007-05-25 13:17:15 -0700 (Fri, 25 May 2007) | 3 lines Remove direct call's to file's constructor and replace them with calls to open() as ths is considered best practice. ........ r55601 | kristjan.jonsson | 2007-05-26 12:19:50 -0700 (Sat, 26 May 2007) | 1 line Remove the rgbimgmodule from PCBuild8 ........ r55602 | kristjan.jonsson | 2007-05-26 12:31:39 -0700 (Sat, 26 May 2007) | 1 line Include <windows.h> after python.h, so that WINNT is properly set before windows.h is included. Fixes warnings in PC builds. ........ r55603 | walter.doerwald | 2007-05-26 14:04:13 -0700 (Sat, 26 May 2007) | 2 lines Fix typo. ........ r55604 | peter.astrand | 2007-05-26 15:18:20 -0700 (Sat, 26 May 2007) | 1 line Applied patch 1669481, slightly modified: Support close_fds on Win32 ........ r55606 | neal.norwitz | 2007-05-26 21:08:54 -0700 (Sat, 26 May 2007) | 2 lines Add the new function object attribute names from py3k. ........ r55617 | lars.gustaebel | 2007-05-27 12:49:30 -0700 (Sun, 27 May 2007) | 20 lines Added errors argument to TarFile class that allows the user to specify an error handling scheme for character conversion. Additional scheme "utf-8" in read mode. Unicode input filenames are now supported by design. The values of the pax_headers dictionary are now limited to unicode objects. Fixed: The prefix field is no longer used in PAX_FORMAT (in conformance with POSIX). Fixed: In read mode use a possible pax header size field. Fixed: Strip trailing slashes from pax header name values. Fixed: Give values in user-specified pax_headers precedence when writing. Added unicode tests. Added pax/regtype4 member to testtar.tar all possible number fields in a pax header. Added two chapters to the documentation about the different formats tarfile.py supports and how unicode issues are handled. ........ r55618 | raymond.hettinger | 2007-05-27 22:23:22 -0700 (Sun, 27 May 2007) | 1 line Explain when groupby() issues a new group. ........ r55634 | martin.v.loewis | 2007-05-28 21:01:29 -0700 (Mon, 28 May 2007) | 2 lines Test pre-commit hook for a link to a .py file. ........ r55635 | martin.v.loewis | 2007-05-28 21:02:03 -0700 (Mon, 28 May 2007) | 2 lines Revert 55634. ........ ................ r55639 | neal.norwitz | 2007-05-29 00:58:11 -0700 (Tue, 29 May 2007) | 1 line Remove sys.exc_{type,exc_value,exc_traceback} ................ r55641 | neal.norwitz | 2007-05-29 01:03:50 -0700 (Tue, 29 May 2007) | 1 line Missed one sys.exc_type. I wonder why exc_{value,traceback} were already gone ................ r55642 | neal.norwitz | 2007-05-29 01:08:33 -0700 (Tue, 29 May 2007) | 1 line Missed more doc for sys.exc_* attrs. ................ r55643 | neal.norwitz | 2007-05-29 01:18:19 -0700 (Tue, 29 May 2007) | 1 line Remove sys.exc_clear() ................ r55665 | guido.van.rossum | 2007-05-29 19:45:43 -0700 (Tue, 29 May 2007) | 4 lines Make None, True, False keywords. We can now also delete all the other places that explicitly forbid assignment to None, but I'm not going to bother right now. ................ r55666 | guido.van.rossum | 2007-05-29 20:01:51 -0700 (Tue, 29 May 2007) | 3 lines Found another place that needs check for forbidden names. Fixed test_syntax.py accordingly (it helped me find that one). ................ r55668 | guido.van.rossum | 2007-05-29 20:41:48 -0700 (Tue, 29 May 2007) | 2 lines Mark None, True, False as keywords. ................ r55673 | neal.norwitz | 2007-05-29 23:28:25 -0700 (Tue, 29 May 2007) | 3 lines Get the dis module working on modules again after changing dicts to not return lists and also new-style classes. Add a test. ................ r55674 | neal.norwitz | 2007-05-29 23:35:45 -0700 (Tue, 29 May 2007) | 1 line Umm, it helps to add the module that the test uses ................ r55675 | neal.norwitz | 2007-05-29 23:53:05 -0700 (Tue, 29 May 2007) | 4 lines Try to fix up all the other places that were assigning to True/False. There's at least one more problem in test.test_xmlrpc. I have other changes in that file and that should be fixed soon (I hope). ................ r55679 | neal.norwitz | 2007-05-30 00:31:55 -0700 (Wed, 30 May 2007) | 1 line Fix up another place that was assigning to True/False. ................ r55688 | brett.cannon | 2007-05-30 14:19:47 -0700 (Wed, 30 May 2007) | 2 lines Ditch MimeWriter. ................ r55692 | brett.cannon | 2007-05-30 14:52:00 -0700 (Wed, 30 May 2007) | 2 lines Remove the mimify module. ................ r55707 | guido.van.rossum | 2007-05-31 05:08:45 -0700 (Thu, 31 May 2007) | 2 lines Backport the addition of show_code() to dis.py -- it's too handy. ................ r55708 | guido.van.rossum | 2007-05-31 06:22:57 -0700 (Thu, 31 May 2007) | 7 lines Fix a fairly long-standing bug in the check for assignment to None (and other keywords, these days). In 2.5, you could write foo(None=1) without getting a SyntaxError (although foo()'s definition would have to use **kwds to avoid getting a runtime error complaining about an unknown keyword of course). This ought to be backported to 2.5.2 or at least 2.6. ................ r55724 | brett.cannon | 2007-05-31 19:32:41 -0700 (Thu, 31 May 2007) | 2 lines Remove the cfmfile. ................ r55727 | neal.norwitz | 2007-05-31 22:19:44 -0700 (Thu, 31 May 2007) | 1 line Remove reload() builtin. ................ r55729 | neal.norwitz | 2007-05-31 22:51:30 -0700 (Thu, 31 May 2007) | 59 lines Merged revisions 55636-55728 via svnmerge from svn+ssh://pythondev@svn.python.org/python/trunk ........ r55637 | georg.brandl | 2007-05-29 00:16:47 -0700 (Tue, 29 May 2007) | 2 lines Fix rst markup. ........ r55638 | neal.norwitz | 2007-05-29 00:51:39 -0700 (Tue, 29 May 2007) | 1 line Fix typo in doc ........ r55671 | neal.norwitz | 2007-05-29 21:53:41 -0700 (Tue, 29 May 2007) | 1 line Fix indentation (whitespace only). ........ r55676 | thomas.heller | 2007-05-29 23:58:30 -0700 (Tue, 29 May 2007) | 1 line Fix compiler warnings. ........ r55677 | thomas.heller | 2007-05-30 00:01:25 -0700 (Wed, 30 May 2007) | 2 lines Correct the name of a field in the WIN32_FIND_DATAA and WIN32_FIND_DATAW structures. Closes bug #1726026. ........ r55686 | brett.cannon | 2007-05-30 13:46:26 -0700 (Wed, 30 May 2007) | 2 lines Have MimeWriter raise a DeprecationWarning as per PEP 4 and its documentation. ........ r55690 | brett.cannon | 2007-05-30 14:48:58 -0700 (Wed, 30 May 2007) | 3 lines Have mimify raise a DeprecationWarning. The docs and PEP 4 have listed the module as deprecated for a while. ........ r55696 | brett.cannon | 2007-05-30 15:24:28 -0700 (Wed, 30 May 2007) | 2 lines Have md5 raise a DeprecationWarning as per PEP 4. ........ r55705 | neal.norwitz | 2007-05-30 21:14:22 -0700 (Wed, 30 May 2007) | 1 line Add some spaces in the example code. ........ r55716 | brett.cannon | 2007-05-31 12:20:00 -0700 (Thu, 31 May 2007) | 2 lines Have the sha module raise a DeprecationWarning as specified in PEP 4. ........ r55719 | brett.cannon | 2007-05-31 12:40:42 -0700 (Thu, 31 May 2007) | 2 lines Cause buildtools to raise a DeprecationWarning. ........ r55721 | brett.cannon | 2007-05-31 13:01:11 -0700 (Thu, 31 May 2007) | 2 lines Have cfmfile raise a DeprecationWarning as per PEP 4. ........ r55726 | neal.norwitz | 2007-05-31 21:56:47 -0700 (Thu, 31 May 2007) | 1 line Mail if there is an installation failure. ........ ................ r55730 | neal.norwitz | 2007-05-31 23:22:07 -0700 (Thu, 31 May 2007) | 2 lines Remove the code that was missed in rev 55303. ................ r55738 | neal.norwitz | 2007-06-01 19:10:43 -0700 (Fri, 01 Jun 2007) | 1 line Fix doc breakage ................ r55741 | neal.norwitz | 2007-06-02 00:41:58 -0700 (Sat, 02 Jun 2007) | 1 line Remove timing module (plus some remnants of other modules). ................ r55742 | neal.norwitz | 2007-06-02 00:51:44 -0700 (Sat, 02 Jun 2007) | 1 line Remove posixfile module (plus some remnants of other modules). ................ r55744 | neal.norwitz | 2007-06-02 10:18:56 -0700 (Sat, 02 Jun 2007) | 1 line Fix doc breakage. ................ r55745 | neal.norwitz | 2007-06-02 11:32:16 -0700 (Sat, 02 Jun 2007) | 1 line Make a whatsnew 3.0 template. ................ r55754 | neal.norwitz | 2007-06-03 23:24:18 -0700 (Sun, 03 Jun 2007) | 1 line SF #1730441, os._execvpe raises UnboundLocal due to new try/except semantics ................ r55755 | neal.norwitz | 2007-06-03 23:26:00 -0700 (Sun, 03 Jun 2007) | 1 line Get rid of extra whitespace ................ r55794 | guido.van.rossum | 2007-06-06 15:29:22 -0700 (Wed, 06 Jun 2007) | 3 lines Make this compile in GCC 2.96, which does not allow interspersing declarations and code. ................
1768 lines
72 KiB
TeX
1768 lines
72 KiB
TeX
\section{\module{logging} ---
|
|
Logging facility for Python}
|
|
|
|
\declaremodule{standard}{logging}
|
|
|
|
% These apply to all modules, and may be given more than once:
|
|
|
|
\moduleauthor{Vinay Sajip}{vinay_sajip@red-dove.com}
|
|
\sectionauthor{Vinay Sajip}{vinay_sajip@red-dove.com}
|
|
|
|
\modulesynopsis{Logging module for Python based on \pep{282}.}
|
|
|
|
\indexii{Errors}{logging}
|
|
|
|
\versionadded{2.3}
|
|
This module defines functions and classes which implement a flexible
|
|
error logging system for applications.
|
|
|
|
Logging is performed by calling methods on instances of the
|
|
\class{Logger} class (hereafter called \dfn{loggers}). Each instance has a
|
|
name, and they are conceptually arranged in a name space hierarchy
|
|
using dots (periods) as separators. For example, a logger named
|
|
"scan" is the parent of loggers "scan.text", "scan.html" and "scan.pdf".
|
|
Logger names can be anything you want, and indicate the area of an
|
|
application in which a logged message originates.
|
|
|
|
Logged messages also have levels of importance associated with them.
|
|
The default levels provided are \constant{DEBUG}, \constant{INFO},
|
|
\constant{WARNING}, \constant{ERROR} and \constant{CRITICAL}. As a
|
|
convenience, you indicate the importance of a logged message by calling
|
|
an appropriate method of \class{Logger}. The methods are
|
|
\method{debug()}, \method{info()}, \method{warning()}, \method{error()} and
|
|
\method{critical()}, which mirror the default levels. You are not
|
|
constrained to use these levels: you can specify your own and use a
|
|
more general \class{Logger} method, \method{log()}, which takes an
|
|
explicit level argument.
|
|
|
|
The numeric values of logging levels are given in the following table. These
|
|
are primarily of interest if you want to define your own levels, and need
|
|
them to have specific values relative to the predefined levels. If you
|
|
define a level with the same numeric value, it overwrites the predefined
|
|
value; the predefined name is lost.
|
|
|
|
\begin{tableii}{l|l}{code}{Level}{Numeric value}
|
|
\lineii{CRITICAL}{50}
|
|
\lineii{ERROR}{40}
|
|
\lineii{WARNING}{30}
|
|
\lineii{INFO}{20}
|
|
\lineii{DEBUG}{10}
|
|
\lineii{NOTSET}{0}
|
|
\end{tableii}
|
|
|
|
Levels can also be associated with loggers, being set either by the
|
|
developer or through loading a saved logging configuration. When a
|
|
logging method is called on a logger, the logger compares its own
|
|
level with the level associated with the method call. If the logger's
|
|
level is higher than the method call's, no logging message is actually
|
|
generated. This is the basic mechanism controlling the verbosity of
|
|
logging output.
|
|
|
|
Logging messages are encoded as instances of the \class{LogRecord} class.
|
|
When a logger decides to actually log an event, a \class{LogRecord}
|
|
instance is created from the logging message.
|
|
|
|
Logging messages are subjected to a dispatch mechanism through the
|
|
use of \dfn{handlers}, which are instances of subclasses of the
|
|
\class{Handler} class. Handlers are responsible for ensuring that a logged
|
|
message (in the form of a \class{LogRecord}) ends up in a particular
|
|
location (or set of locations) which is useful for the target audience for
|
|
that message (such as end users, support desk staff, system administrators,
|
|
developers). Handlers are passed \class{LogRecord} instances intended for
|
|
particular destinations. Each logger can have zero, one or more handlers
|
|
associated with it (via the \method{addHandler()} method of \class{Logger}).
|
|
In addition to any handlers directly associated with a logger,
|
|
\emph{all handlers associated with all ancestors of the logger} are
|
|
called to dispatch the message.
|
|
|
|
Just as for loggers, handlers can have levels associated with them.
|
|
A handler's level acts as a filter in the same way as a logger's level does.
|
|
If a handler decides to actually dispatch an event, the \method{emit()} method
|
|
is used to send the message to its destination. Most user-defined subclasses
|
|
of \class{Handler} will need to override this \method{emit()}.
|
|
|
|
In addition to the base \class{Handler} class, many useful subclasses
|
|
are provided:
|
|
|
|
\begin{enumerate}
|
|
|
|
\item \class{StreamHandler} instances send error messages to
|
|
streams (file-like objects).
|
|
|
|
\item \class{FileHandler} instances send error messages to disk
|
|
files.
|
|
|
|
\item \class{BaseRotatingHandler} is the base class for handlers that
|
|
rotate log files at a certain point. It is not meant to be instantiated
|
|
directly. Instead, use \class{RotatingFileHandler} or
|
|
\class{TimedRotatingFileHandler}.
|
|
|
|
\item \class{RotatingFileHandler} instances send error messages to disk
|
|
files, with support for maximum log file sizes and log file rotation.
|
|
|
|
\item \class{TimedRotatingFileHandler} instances send error messages to
|
|
disk files rotating the log file at certain timed intervals.
|
|
|
|
\item \class{SocketHandler} instances send error messages to
|
|
TCP/IP sockets.
|
|
|
|
\item \class{DatagramHandler} instances send error messages to UDP
|
|
sockets.
|
|
|
|
\item \class{SMTPHandler} instances send error messages to a
|
|
designated email address.
|
|
|
|
\item \class{SysLogHandler} instances send error messages to a
|
|
\UNIX{} syslog daemon, possibly on a remote machine.
|
|
|
|
\item \class{NTEventLogHandler} instances send error messages to a
|
|
Windows NT/2000/XP event log.
|
|
|
|
\item \class{MemoryHandler} instances send error messages to a
|
|
buffer in memory, which is flushed whenever specific criteria are
|
|
met.
|
|
|
|
\item \class{HTTPHandler} instances send error messages to an
|
|
HTTP server using either \samp{GET} or \samp{POST} semantics.
|
|
|
|
\end{enumerate}
|
|
|
|
The \class{StreamHandler} and \class{FileHandler} classes are defined
|
|
in the core logging package. The other handlers are defined in a sub-
|
|
module, \module{logging.handlers}. (There is also another sub-module,
|
|
\module{logging.config}, for configuration functionality.)
|
|
|
|
Logged messages are formatted for presentation through instances of the
|
|
\class{Formatter} class. They are initialized with a format string
|
|
suitable for use with the \% operator and a dictionary.
|
|
|
|
For formatting multiple messages in a batch, instances of
|
|
\class{BufferingFormatter} can be used. In addition to the format string
|
|
(which is applied to each message in the batch), there is provision for
|
|
header and trailer format strings.
|
|
|
|
When filtering based on logger level and/or handler level is not enough,
|
|
instances of \class{Filter} can be added to both \class{Logger} and
|
|
\class{Handler} instances (through their \method{addFilter()} method).
|
|
Before deciding to process a message further, both loggers and handlers
|
|
consult all their filters for permission. If any filter returns a false
|
|
value, the message is not processed further.
|
|
|
|
The basic \class{Filter} functionality allows filtering by specific logger
|
|
name. If this feature is used, messages sent to the named logger and its
|
|
children are allowed through the filter, and all others dropped.
|
|
|
|
In addition to the classes described above, there are a number of module-
|
|
level functions.
|
|
|
|
\begin{funcdesc}{getLogger}{\optional{name}}
|
|
Return a logger with the specified name or, if no name is specified, return
|
|
a logger which is the root logger of the hierarchy. If specified, the name
|
|
is typically a dot-separated hierarchical name like \var{"a"}, \var{"a.b"}
|
|
or \var{"a.b.c.d"}. Choice of these names is entirely up to the developer
|
|
who is using logging.
|
|
|
|
All calls to this function with a given name return the same logger instance.
|
|
This means that logger instances never need to be passed between different
|
|
parts of an application.
|
|
\end{funcdesc}
|
|
|
|
\begin{funcdesc}{getLoggerClass}{}
|
|
Return either the standard \class{Logger} class, or the last class passed to
|
|
\function{setLoggerClass()}. This function may be called from within a new
|
|
class definition, to ensure that installing a customised \class{Logger} class
|
|
will not undo customisations already applied by other code. For example:
|
|
|
|
\begin{verbatim}
|
|
class MyLogger(logging.getLoggerClass()):
|
|
# ... override behaviour here
|
|
\end{verbatim}
|
|
|
|
\end{funcdesc}
|
|
|
|
\begin{funcdesc}{debug}{msg\optional{, *args\optional{, **kwargs}}}
|
|
Logs a message with level \constant{DEBUG} on the root logger.
|
|
The \var{msg} is the message format string, and the \var{args} are the
|
|
arguments which are merged into \var{msg} using the string formatting
|
|
operator. (Note that this means that you can use keywords in the
|
|
format string, together with a single dictionary argument.)
|
|
|
|
There are two keyword arguments in \var{kwargs} which are inspected:
|
|
\var{exc_info} which, if it does not evaluate as false, causes exception
|
|
information to be added to the logging message. If an exception tuple (in the
|
|
format returned by \function{sys.exc_info()}) is provided, it is used;
|
|
otherwise, \function{sys.exc_info()} is called to get the exception
|
|
information.
|
|
|
|
The other optional keyword argument is \var{extra} which can be used to pass
|
|
a dictionary which is used to populate the __dict__ of the LogRecord created
|
|
for the logging event with user-defined attributes. These custom attributes
|
|
can then be used as you like. For example, they could be incorporated into
|
|
logged messages. For example:
|
|
|
|
\begin{verbatim}
|
|
FORMAT = "%(asctime)-15s %(clientip)s %(user)-8s %(message)s"
|
|
logging.basicConfig(format=FORMAT)
|
|
d = {'clientip': '192.168.0.1', 'user': 'fbloggs'}
|
|
logging.warning("Protocol problem: %s", "connection reset", extra=d)
|
|
\end{verbatim}
|
|
|
|
would print something like
|
|
\begin{verbatim}
|
|
2006-02-08 22:20:02,165 192.168.0.1 fbloggs Protocol problem: connection reset
|
|
\end{verbatim}
|
|
|
|
The keys in the dictionary passed in \var{extra} should not clash with the keys
|
|
used by the logging system. (See the \class{Formatter} documentation for more
|
|
information on which keys are used by the logging system.)
|
|
|
|
If you choose to use these attributes in logged messages, you need to exercise
|
|
some care. In the above example, for instance, the \class{Formatter} has been
|
|
set up with a format string which expects 'clientip' and 'user' in the
|
|
attribute dictionary of the LogRecord. If these are missing, the message will
|
|
not be logged because a string formatting exception will occur. So in this
|
|
case, you always need to pass the \var{extra} dictionary with these keys.
|
|
|
|
While this might be annoying, this feature is intended for use in specialized
|
|
circumstances, such as multi-threaded servers where the same code executes
|
|
in many contexts, and interesting conditions which arise are dependent on this
|
|
context (such as remote client IP address and authenticated user name, in the
|
|
above example). In such circumstances, it is likely that specialized
|
|
\class{Formatter}s would be used with particular \class{Handler}s.
|
|
|
|
\versionchanged[\var{extra} was added]{2.5}
|
|
|
|
\end{funcdesc}
|
|
|
|
\begin{funcdesc}{info}{msg\optional{, *args\optional{, **kwargs}}}
|
|
Logs a message with level \constant{INFO} on the root logger.
|
|
The arguments are interpreted as for \function{debug()}.
|
|
\end{funcdesc}
|
|
|
|
\begin{funcdesc}{warning}{msg\optional{, *args\optional{, **kwargs}}}
|
|
Logs a message with level \constant{WARNING} on the root logger.
|
|
The arguments are interpreted as for \function{debug()}.
|
|
\end{funcdesc}
|
|
|
|
\begin{funcdesc}{error}{msg\optional{, *args\optional{, **kwargs}}}
|
|
Logs a message with level \constant{ERROR} on the root logger.
|
|
The arguments are interpreted as for \function{debug()}.
|
|
\end{funcdesc}
|
|
|
|
\begin{funcdesc}{critical}{msg\optional{, *args\optional{, **kwargs}}}
|
|
Logs a message with level \constant{CRITICAL} on the root logger.
|
|
The arguments are interpreted as for \function{debug()}.
|
|
\end{funcdesc}
|
|
|
|
\begin{funcdesc}{exception}{msg\optional{, *args}}
|
|
Logs a message with level \constant{ERROR} on the root logger.
|
|
The arguments are interpreted as for \function{debug()}. Exception info
|
|
is added to the logging message. This function should only be called
|
|
from an exception handler.
|
|
\end{funcdesc}
|
|
|
|
\begin{funcdesc}{log}{level, msg\optional{, *args\optional{, **kwargs}}}
|
|
Logs a message with level \var{level} on the root logger.
|
|
The other arguments are interpreted as for \function{debug()}.
|
|
\end{funcdesc}
|
|
|
|
\begin{funcdesc}{disable}{lvl}
|
|
Provides an overriding level \var{lvl} for all loggers which takes
|
|
precedence over the logger's own level. When the need arises to
|
|
temporarily throttle logging output down across the whole application,
|
|
this function can be useful.
|
|
\end{funcdesc}
|
|
|
|
\begin{funcdesc}{addLevelName}{lvl, levelName}
|
|
Associates level \var{lvl} with text \var{levelName} in an internal
|
|
dictionary, which is used to map numeric levels to a textual
|
|
representation, for example when a \class{Formatter} formats a message.
|
|
This function can also be used to define your own levels. The only
|
|
constraints are that all levels used must be registered using this
|
|
function, levels should be positive integers and they should increase
|
|
in increasing order of severity.
|
|
\end{funcdesc}
|
|
|
|
\begin{funcdesc}{getLevelName}{lvl}
|
|
Returns the textual representation of logging level \var{lvl}. If the
|
|
level is one of the predefined levels \constant{CRITICAL},
|
|
\constant{ERROR}, \constant{WARNING}, \constant{INFO} or \constant{DEBUG}
|
|
then you get the corresponding string. If you have associated levels
|
|
with names using \function{addLevelName()} then the name you have associated
|
|
with \var{lvl} is returned. If a numeric value corresponding to one of the
|
|
defined levels is passed in, the corresponding string representation is
|
|
returned. Otherwise, the string "Level \%s" \% lvl is returned.
|
|
\end{funcdesc}
|
|
|
|
\begin{funcdesc}{makeLogRecord}{attrdict}
|
|
Creates and returns a new \class{LogRecord} instance whose attributes are
|
|
defined by \var{attrdict}. This function is useful for taking a pickled
|
|
\class{LogRecord} attribute dictionary, sent over a socket, and reconstituting
|
|
it as a \class{LogRecord} instance at the receiving end.
|
|
\end{funcdesc}
|
|
|
|
\begin{funcdesc}{basicConfig}{\optional{**kwargs}}
|
|
Does basic configuration for the logging system by creating a
|
|
\class{StreamHandler} with a default \class{Formatter} and adding it to
|
|
the root logger. The functions \function{debug()}, \function{info()},
|
|
\function{warning()}, \function{error()} and \function{critical()} will call
|
|
\function{basicConfig()} automatically if no handlers are defined for the
|
|
root logger.
|
|
|
|
\versionchanged[Formerly, \function{basicConfig} did not take any keyword
|
|
arguments]{2.4}
|
|
|
|
The following keyword arguments are supported.
|
|
|
|
\begin{tableii}{l|l}{code}{Format}{Description}
|
|
\lineii{filename}{Specifies that a FileHandler be created, using the
|
|
specified filename, rather than a StreamHandler.}
|
|
\lineii{filemode}{Specifies the mode to open the file, if filename is
|
|
specified (if filemode is unspecified, it defaults to 'a').}
|
|
\lineii{format}{Use the specified format string for the handler.}
|
|
\lineii{datefmt}{Use the specified date/time format.}
|
|
\lineii{level}{Set the root logger level to the specified level.}
|
|
\lineii{stream}{Use the specified stream to initialize the StreamHandler.
|
|
Note that this argument is incompatible with 'filename' - if both
|
|
are present, 'stream' is ignored.}
|
|
\end{tableii}
|
|
|
|
\end{funcdesc}
|
|
|
|
\begin{funcdesc}{shutdown}{}
|
|
Informs the logging system to perform an orderly shutdown by flushing and
|
|
closing all handlers.
|
|
\end{funcdesc}
|
|
|
|
\begin{funcdesc}{setLoggerClass}{klass}
|
|
Tells the logging system to use the class \var{klass} when instantiating a
|
|
logger. The class should define \method{__init__()} such that only a name
|
|
argument is required, and the \method{__init__()} should call
|
|
\method{Logger.__init__()}. This function is typically called before any
|
|
loggers are instantiated by applications which need to use custom logger
|
|
behavior.
|
|
\end{funcdesc}
|
|
|
|
|
|
\begin{seealso}
|
|
\seepep{282}{A Logging System}
|
|
{The proposal which described this feature for inclusion in
|
|
the Python standard library.}
|
|
\seelink{http://www.red-dove.com/python_logging.html}
|
|
{Original Python \module{logging} package}
|
|
{This is the original source for the \module{logging}
|
|
package. The version of the package available from this
|
|
site is suitable for use with Python 1.5.2, 2.1.x and 2.2.x,
|
|
which do not include the \module{logging} package in the standard
|
|
library.}
|
|
\end{seealso}
|
|
|
|
|
|
\subsection{Logger Objects}
|
|
|
|
Loggers have the following attributes and methods. Note that Loggers are
|
|
never instantiated directly, but always through the module-level function
|
|
\function{logging.getLogger(name)}.
|
|
|
|
\begin{memberdesc}[Logger]{propagate}
|
|
If this evaluates to false, logging messages are not passed by this
|
|
logger or by child loggers to higher level (ancestor) loggers. The
|
|
constructor sets this attribute to 1.
|
|
\end{memberdesc}
|
|
|
|
\begin{methoddesc}[Logger]{setLevel}{lvl}
|
|
Sets the threshold for this logger to \var{lvl}. Logging messages
|
|
which are less severe than \var{lvl} will be ignored. When a logger is
|
|
created, the level is set to \constant{NOTSET} (which causes all messages
|
|
to be processed when the logger is the root logger, or delegation to the
|
|
parent when the logger is a non-root logger). Note that the root logger
|
|
is created with level \constant{WARNING}.
|
|
|
|
The term "delegation to the parent" means that if a logger has a level
|
|
of NOTSET, its chain of ancestor loggers is traversed until either an
|
|
ancestor with a level other than NOTSET is found, or the root is
|
|
reached.
|
|
|
|
If an ancestor is found with a level other than NOTSET, then that
|
|
ancestor's level is treated as the effective level of the logger where
|
|
the ancestor search began, and is used to determine how a logging
|
|
event is handled.
|
|
|
|
If the root is reached, and it has a level of NOTSET, then all
|
|
messages will be processed. Otherwise, the root's level will be used
|
|
as the effective level.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}[Logger]{isEnabledFor}{lvl}
|
|
Indicates if a message of severity \var{lvl} would be processed by
|
|
this logger. This method checks first the module-level level set by
|
|
\function{logging.disable(lvl)} and then the logger's effective level as
|
|
determined by \method{getEffectiveLevel()}.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}[Logger]{getEffectiveLevel}{}
|
|
Indicates the effective level for this logger. If a value other than
|
|
\constant{NOTSET} has been set using \method{setLevel()}, it is returned.
|
|
Otherwise, the hierarchy is traversed towards the root until a value
|
|
other than \constant{NOTSET} is found, and that value is returned.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}[Logger]{debug}{msg\optional{, *args\optional{, **kwargs}}}
|
|
Logs a message with level \constant{DEBUG} on this logger.
|
|
The \var{msg} is the message format string, and the \var{args} are the
|
|
arguments which are merged into \var{msg} using the string formatting
|
|
operator. (Note that this means that you can use keywords in the
|
|
format string, together with a single dictionary argument.)
|
|
|
|
There are two keyword arguments in \var{kwargs} which are inspected:
|
|
\var{exc_info} which, if it does not evaluate as false, causes exception
|
|
information to be added to the logging message. If an exception tuple (in the
|
|
format returned by \function{sys.exc_info()}) is provided, it is used;
|
|
otherwise, \function{sys.exc_info()} is called to get the exception
|
|
information.
|
|
|
|
The other optional keyword argument is \var{extra} which can be used to pass
|
|
a dictionary which is used to populate the __dict__ of the LogRecord created
|
|
for the logging event with user-defined attributes. These custom attributes
|
|
can then be used as you like. For example, they could be incorporated into
|
|
logged messages. For example:
|
|
|
|
\begin{verbatim}
|
|
FORMAT = "%(asctime)-15s %(clientip)s %(user)-8s %(message)s"
|
|
logging.basicConfig(format=FORMAT)
|
|
dict = { 'clientip' : '192.168.0.1', 'user' : 'fbloggs' }
|
|
logger = logging.getLogger("tcpserver")
|
|
logger.warning("Protocol problem: %s", "connection reset", extra=d)
|
|
\end{verbatim}
|
|
|
|
would print something like
|
|
\begin{verbatim}
|
|
2006-02-08 22:20:02,165 192.168.0.1 fbloggs Protocol problem: connection reset
|
|
\end{verbatim}
|
|
|
|
The keys in the dictionary passed in \var{extra} should not clash with the keys
|
|
used by the logging system. (See the \class{Formatter} documentation for more
|
|
information on which keys are used by the logging system.)
|
|
|
|
If you choose to use these attributes in logged messages, you need to exercise
|
|
some care. In the above example, for instance, the \class{Formatter} has been
|
|
set up with a format string which expects 'clientip' and 'user' in the
|
|
attribute dictionary of the LogRecord. If these are missing, the message will
|
|
not be logged because a string formatting exception will occur. So in this
|
|
case, you always need to pass the \var{extra} dictionary with these keys.
|
|
|
|
While this might be annoying, this feature is intended for use in specialized
|
|
circumstances, such as multi-threaded servers where the same code executes
|
|
in many contexts, and interesting conditions which arise are dependent on this
|
|
context (such as remote client IP address and authenticated user name, in the
|
|
above example). In such circumstances, it is likely that specialized
|
|
\class{Formatter}s would be used with particular \class{Handler}s.
|
|
|
|
\versionchanged[\var{extra} was added]{2.5}
|
|
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}[Logger]{info}{msg\optional{, *args\optional{, **kwargs}}}
|
|
Logs a message with level \constant{INFO} on this logger.
|
|
The arguments are interpreted as for \method{debug()}.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}[Logger]{warning}{msg\optional{, *args\optional{, **kwargs}}}
|
|
Logs a message with level \constant{WARNING} on this logger.
|
|
The arguments are interpreted as for \method{debug()}.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}[Logger]{error}{msg\optional{, *args\optional{, **kwargs}}}
|
|
Logs a message with level \constant{ERROR} on this logger.
|
|
The arguments are interpreted as for \method{debug()}.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}[Logger]{critical}{msg\optional{, *args\optional{, **kwargs}}}
|
|
Logs a message with level \constant{CRITICAL} on this logger.
|
|
The arguments are interpreted as for \method{debug()}.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}[Logger]{log}{lvl, msg\optional{, *args\optional{, **kwargs}}}
|
|
Logs a message with integer level \var{lvl} on this logger.
|
|
The other arguments are interpreted as for \method{debug()}.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}[Logger]{exception}{msg\optional{, *args}}
|
|
Logs a message with level \constant{ERROR} on this logger.
|
|
The arguments are interpreted as for \method{debug()}. Exception info
|
|
is added to the logging message. This method should only be called
|
|
from an exception handler.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}[Logger]{addFilter}{filt}
|
|
Adds the specified filter \var{filt} to this logger.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}[Logger]{removeFilter}{filt}
|
|
Removes the specified filter \var{filt} from this logger.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}[Logger]{filter}{record}
|
|
Applies this logger's filters to the record and returns a true value if
|
|
the record is to be processed.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}[Logger]{addHandler}{hdlr}
|
|
Adds the specified handler \var{hdlr} to this logger.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}[Logger]{removeHandler}{hdlr}
|
|
Removes the specified handler \var{hdlr} from this logger.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}[Logger]{findCaller}{}
|
|
Finds the caller's source filename and line number. Returns the filename,
|
|
line number and function name as a 3-element tuple.
|
|
\versionchanged[The function name was added. In earlier versions, the
|
|
filename and line number were returned as a 2-element tuple.]{2.5}
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}[Logger]{handle}{record}
|
|
Handles a record by passing it to all handlers associated with this logger
|
|
and its ancestors (until a false value of \var{propagate} is found).
|
|
This method is used for unpickled records received from a socket, as well
|
|
as those created locally. Logger-level filtering is applied using
|
|
\method{filter()}.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}[Logger]{makeRecord}{name, lvl, fn, lno, msg, args, exc_info
|
|
\optional{, func, extra}}
|
|
This is a factory method which can be overridden in subclasses to create
|
|
specialized \class{LogRecord} instances.
|
|
\versionchanged[\var{func} and \var{extra} were added]{2.5}
|
|
\end{methoddesc}
|
|
|
|
\subsection{Basic example \label{minimal-example}}
|
|
|
|
\versionchanged[formerly \function{basicConfig} did not take any keyword
|
|
arguments]{2.4}
|
|
|
|
The \module{logging} package provides a lot of flexibility, and its
|
|
configuration can appear daunting. This section demonstrates that simple
|
|
use of the logging package is possible.
|
|
|
|
The simplest example shows logging to the console:
|
|
|
|
\begin{verbatim}
|
|
import logging
|
|
|
|
logging.debug('A debug message')
|
|
logging.info('Some information')
|
|
logging.warning('A shot across the bows')
|
|
\end{verbatim}
|
|
|
|
If you run the above script, you'll see this:
|
|
\begin{verbatim}
|
|
WARNING:root:A shot across the bows
|
|
\end{verbatim}
|
|
|
|
Because no particular logger was specified, the system used the root logger.
|
|
The debug and info messages didn't appear because by default, the root
|
|
logger is configured to only handle messages with a severity of WARNING
|
|
or above. The message format is also a configuration default, as is the output
|
|
destination of the messages - \code{sys.stderr}. The severity level,
|
|
the message format and destination can be easily changed, as shown in
|
|
the example below:
|
|
|
|
\begin{verbatim}
|
|
import logging
|
|
|
|
logging.basicConfig(level=logging.DEBUG,
|
|
format='%(asctime)s %(levelname)s %(message)s',
|
|
filename='/tmp/myapp.log',
|
|
filemode='w')
|
|
logging.debug('A debug message')
|
|
logging.info('Some information')
|
|
logging.warning('A shot across the bows')
|
|
\end{verbatim}
|
|
|
|
The \method{basicConfig()} method is used to change the configuration
|
|
defaults, which results in output (written to \code{/tmp/myapp.log})
|
|
which should look something like the following:
|
|
|
|
\begin{verbatim}
|
|
2004-07-02 13:00:08,743 DEBUG A debug message
|
|
2004-07-02 13:00:08,743 INFO Some information
|
|
2004-07-02 13:00:08,743 WARNING A shot across the bows
|
|
\end{verbatim}
|
|
|
|
This time, all messages with a severity of DEBUG or above were handled,
|
|
and the format of the messages was also changed, and output went to the
|
|
specified file rather than the console.
|
|
|
|
Formatting uses standard Python string formatting - see section
|
|
\ref{typesseq-strings}. The format string takes the following
|
|
common specifiers. For a complete list of specifiers, consult the
|
|
\class{Formatter} documentation.
|
|
|
|
\begin{tableii}{l|l}{code}{Format}{Description}
|
|
\lineii{\%(name)s} {Name of the logger (logging channel).}
|
|
\lineii{\%(levelname)s}{Text logging level for the message
|
|
(\code{'DEBUG'}, \code{'INFO'},
|
|
\code{'WARNING'}, \code{'ERROR'},
|
|
\code{'CRITICAL'}).}
|
|
\lineii{\%(asctime)s} {Human-readable time when the \class{LogRecord}
|
|
was created. By default this is of the form
|
|
``2003-07-08 16:49:45,896'' (the numbers after the
|
|
comma are millisecond portion of the time).}
|
|
\lineii{\%(message)s} {The logged message.}
|
|
\end{tableii}
|
|
|
|
To change the date/time format, you can pass an additional keyword parameter,
|
|
\var{datefmt}, as in the following:
|
|
|
|
\begin{verbatim}
|
|
import logging
|
|
|
|
logging.basicConfig(level=logging.DEBUG,
|
|
format='%(asctime)s %(levelname)-8s %(message)s',
|
|
datefmt='%a, %d %b %Y %H:%M:%S',
|
|
filename='/temp/myapp.log',
|
|
filemode='w')
|
|
logging.debug('A debug message')
|
|
logging.info('Some information')
|
|
logging.warning('A shot across the bows')
|
|
\end{verbatim}
|
|
|
|
which would result in output like
|
|
|
|
\begin{verbatim}
|
|
Fri, 02 Jul 2004 13:06:18 DEBUG A debug message
|
|
Fri, 02 Jul 2004 13:06:18 INFO Some information
|
|
Fri, 02 Jul 2004 13:06:18 WARNING A shot across the bows
|
|
\end{verbatim}
|
|
|
|
The date format string follows the requirements of \function{strftime()} -
|
|
see the documentation for the \refmodule{time} module.
|
|
|
|
If, instead of sending logging output to the console or a file, you'd rather
|
|
use a file-like object which you have created separately, you can pass it
|
|
to \function{basicConfig()} using the \var{stream} keyword argument. Note
|
|
that if both \var{stream} and \var{filename} keyword arguments are passed,
|
|
the \var{stream} argument is ignored.
|
|
|
|
Of course, you can put variable information in your output. To do this,
|
|
simply have the message be a format string and pass in additional arguments
|
|
containing the variable information, as in the following example:
|
|
|
|
\begin{verbatim}
|
|
import logging
|
|
|
|
logging.basicConfig(level=logging.DEBUG,
|
|
format='%(asctime)s %(levelname)-8s %(message)s',
|
|
datefmt='%a, %d %b %Y %H:%M:%S',
|
|
filename='/temp/myapp.log',
|
|
filemode='w')
|
|
logging.error('Pack my box with %d dozen %s', 5, 'liquor jugs')
|
|
\end{verbatim}
|
|
|
|
which would result in
|
|
|
|
\begin{verbatim}
|
|
Wed, 21 Jul 2004 15:35:16 ERROR Pack my box with 5 dozen liquor jugs
|
|
\end{verbatim}
|
|
|
|
\subsection{Logging to multiple destinations \label{multiple-destinations}}
|
|
|
|
Let's say you want to log to console and file with different message formats
|
|
and in differing circumstances. Say you want to log messages with levels
|
|
of DEBUG and higher to file, and those messages at level INFO and higher to
|
|
the console. Let's also assume that the file should contain timestamps, but
|
|
the console messages should not. Here's how you can achieve this:
|
|
|
|
\begin{verbatim}
|
|
import logging
|
|
|
|
# set up logging to file - see previous section for more details
|
|
logging.basicConfig(level=logging.DEBUG,
|
|
format='%(asctime)s %(name)-12s %(levelname)-8s %(message)s',
|
|
datefmt='%m-%d %H:%M',
|
|
filename='/temp/myapp.log',
|
|
filemode='w')
|
|
# define a Handler which writes INFO messages or higher to the sys.stderr
|
|
console = logging.StreamHandler()
|
|
console.setLevel(logging.INFO)
|
|
# set a format which is simpler for console use
|
|
formatter = logging.Formatter('%(name)-12s: %(levelname)-8s %(message)s')
|
|
# tell the handler to use this format
|
|
console.setFormatter(formatter)
|
|
# add the handler to the root logger
|
|
logging.getLogger('').addHandler(console)
|
|
|
|
# Now, we can log to the root logger, or any other logger. First the root...
|
|
logging.info('Jackdaws love my big sphinx of quartz.')
|
|
|
|
# Now, define a couple of other loggers which might represent areas in your
|
|
# application:
|
|
|
|
logger1 = logging.getLogger('myapp.area1')
|
|
logger2 = logging.getLogger('myapp.area2')
|
|
|
|
logger1.debug('Quick zephyrs blow, vexing daft Jim.')
|
|
logger1.info('How quickly daft jumping zebras vex.')
|
|
logger2.warning('Jail zesty vixen who grabbed pay from quack.')
|
|
logger2.error('The five boxing wizards jump quickly.')
|
|
\end{verbatim}
|
|
|
|
When you run this, on the console you will see
|
|
|
|
\begin{verbatim}
|
|
root : INFO Jackdaws love my big sphinx of quartz.
|
|
myapp.area1 : INFO How quickly daft jumping zebras vex.
|
|
myapp.area2 : WARNING Jail zesty vixen who grabbed pay from quack.
|
|
myapp.area2 : ERROR The five boxing wizards jump quickly.
|
|
\end{verbatim}
|
|
|
|
and in the file you will see something like
|
|
|
|
\begin{verbatim}
|
|
10-22 22:19 root INFO Jackdaws love my big sphinx of quartz.
|
|
10-22 22:19 myapp.area1 DEBUG Quick zephyrs blow, vexing daft Jim.
|
|
10-22 22:19 myapp.area1 INFO How quickly daft jumping zebras vex.
|
|
10-22 22:19 myapp.area2 WARNING Jail zesty vixen who grabbed pay from quack.
|
|
10-22 22:19 myapp.area2 ERROR The five boxing wizards jump quickly.
|
|
\end{verbatim}
|
|
|
|
As you can see, the DEBUG message only shows up in the file. The other
|
|
messages are sent to both destinations.
|
|
|
|
This example uses console and file handlers, but you can use any number and
|
|
combination of handlers you choose.
|
|
|
|
\subsection{Sending and receiving logging events across a network
|
|
\label{network-logging}}
|
|
|
|
Let's say you want to send logging events across a network, and handle them
|
|
at the receiving end. A simple way of doing this is attaching a
|
|
\class{SocketHandler} instance to the root logger at the sending end:
|
|
|
|
\begin{verbatim}
|
|
import logging, logging.handlers
|
|
|
|
rootLogger = logging.getLogger('')
|
|
rootLogger.setLevel(logging.DEBUG)
|
|
socketHandler = logging.handlers.SocketHandler('localhost',
|
|
logging.handlers.DEFAULT_TCP_LOGGING_PORT)
|
|
# don't bother with a formatter, since a socket handler sends the event as
|
|
# an unformatted pickle
|
|
rootLogger.addHandler(socketHandler)
|
|
|
|
# Now, we can log to the root logger, or any other logger. First the root...
|
|
logging.info('Jackdaws love my big sphinx of quartz.')
|
|
|
|
# Now, define a couple of other loggers which might represent areas in your
|
|
# application:
|
|
|
|
logger1 = logging.getLogger('myapp.area1')
|
|
logger2 = logging.getLogger('myapp.area2')
|
|
|
|
logger1.debug('Quick zephyrs blow, vexing daft Jim.')
|
|
logger1.info('How quickly daft jumping zebras vex.')
|
|
logger2.warning('Jail zesty vixen who grabbed pay from quack.')
|
|
logger2.error('The five boxing wizards jump quickly.')
|
|
\end{verbatim}
|
|
|
|
At the receiving end, you can set up a receiver using the
|
|
\module{SocketServer} module. Here is a basic working example:
|
|
|
|
\begin{verbatim}
|
|
import cPickle
|
|
import logging
|
|
import logging.handlers
|
|
import SocketServer
|
|
import struct
|
|
|
|
|
|
class LogRecordStreamHandler(SocketServer.StreamRequestHandler):
|
|
"""Handler for a streaming logging request.
|
|
|
|
This basically logs the record using whatever logging policy is
|
|
configured locally.
|
|
"""
|
|
|
|
def handle(self):
|
|
"""
|
|
Handle multiple requests - each expected to be a 4-byte length,
|
|
followed by the LogRecord in pickle format. Logs the record
|
|
according to whatever policy is configured locally.
|
|
"""
|
|
while 1:
|
|
chunk = self.connection.recv(4)
|
|
if len(chunk) < 4:
|
|
break
|
|
slen = struct.unpack(">L", chunk)[0]
|
|
chunk = self.connection.recv(slen)
|
|
while len(chunk) < slen:
|
|
chunk = chunk + self.connection.recv(slen - len(chunk))
|
|
obj = self.unPickle(chunk)
|
|
record = logging.makeLogRecord(obj)
|
|
self.handleLogRecord(record)
|
|
|
|
def unPickle(self, data):
|
|
return cPickle.loads(data)
|
|
|
|
def handleLogRecord(self, record):
|
|
# if a name is specified, we use the named logger rather than the one
|
|
# implied by the record.
|
|
if self.server.logname is not None:
|
|
name = self.server.logname
|
|
else:
|
|
name = record.name
|
|
logger = logging.getLogger(name)
|
|
# N.B. EVERY record gets logged. This is because Logger.handle
|
|
# is normally called AFTER logger-level filtering. If you want
|
|
# to do filtering, do it at the client end to save wasting
|
|
# cycles and network bandwidth!
|
|
logger.handle(record)
|
|
|
|
class LogRecordSocketReceiver(SocketServer.ThreadingTCPServer):
|
|
"""simple TCP socket-based logging receiver suitable for testing.
|
|
"""
|
|
|
|
allow_reuse_address = 1
|
|
|
|
def __init__(self, host='localhost',
|
|
port=logging.handlers.DEFAULT_TCP_LOGGING_PORT,
|
|
handler=LogRecordStreamHandler):
|
|
SocketServer.ThreadingTCPServer.__init__(self, (host, port), handler)
|
|
self.abort = 0
|
|
self.timeout = 1
|
|
self.logname = None
|
|
|
|
def serve_until_stopped(self):
|
|
import select
|
|
abort = 0
|
|
while not abort:
|
|
rd, wr, ex = select.select([self.socket.fileno()],
|
|
[], [],
|
|
self.timeout)
|
|
if rd:
|
|
self.handle_request()
|
|
abort = self.abort
|
|
|
|
def main():
|
|
logging.basicConfig(
|
|
format="%(relativeCreated)5d %(name)-15s %(levelname)-8s %(message)s")
|
|
tcpserver = LogRecordSocketReceiver()
|
|
print "About to start TCP server..."
|
|
tcpserver.serve_until_stopped()
|
|
|
|
if __name__ == "__main__":
|
|
main()
|
|
\end{verbatim}
|
|
|
|
First run the server, and then the client. On the client side, nothing is
|
|
printed on the console; on the server side, you should see something like:
|
|
|
|
\begin{verbatim}
|
|
About to start TCP server...
|
|
59 root INFO Jackdaws love my big sphinx of quartz.
|
|
59 myapp.area1 DEBUG Quick zephyrs blow, vexing daft Jim.
|
|
69 myapp.area1 INFO How quickly daft jumping zebras vex.
|
|
69 myapp.area2 WARNING Jail zesty vixen who grabbed pay from quack.
|
|
69 myapp.area2 ERROR The five boxing wizards jump quickly.
|
|
\end{verbatim}
|
|
|
|
\subsection{Handler Objects}
|
|
|
|
Handlers have the following attributes and methods. Note that
|
|
\class{Handler} is never instantiated directly; this class acts as a
|
|
base for more useful subclasses. However, the \method{__init__()}
|
|
method in subclasses needs to call \method{Handler.__init__()}.
|
|
|
|
\begin{methoddesc}[Handler]{__init__}{level=\constant{NOTSET}}
|
|
Initializes the \class{Handler} instance by setting its level, setting
|
|
the list of filters to the empty list and creating a lock (using
|
|
\method{createLock()}) for serializing access to an I/O mechanism.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}[Handler]{createLock}{}
|
|
Initializes a thread lock which can be used to serialize access to
|
|
underlying I/O functionality which may not be threadsafe.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}[Handler]{acquire}{}
|
|
Acquires the thread lock created with \method{createLock()}.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}[Handler]{release}{}
|
|
Releases the thread lock acquired with \method{acquire()}.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}[Handler]{setLevel}{lvl}
|
|
Sets the threshold for this handler to \var{lvl}. Logging messages which are
|
|
less severe than \var{lvl} will be ignored. When a handler is created, the
|
|
level is set to \constant{NOTSET} (which causes all messages to be processed).
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}[Handler]{setFormatter}{form}
|
|
Sets the \class{Formatter} for this handler to \var{form}.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}[Handler]{addFilter}{filt}
|
|
Adds the specified filter \var{filt} to this handler.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}[Handler]{removeFilter}{filt}
|
|
Removes the specified filter \var{filt} from this handler.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}[Handler]{filter}{record}
|
|
Applies this handler's filters to the record and returns a true value if
|
|
the record is to be processed.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}[Handler]{flush}{}
|
|
Ensure all logging output has been flushed. This version does
|
|
nothing and is intended to be implemented by subclasses.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}[Handler]{close}{}
|
|
Tidy up any resources used by the handler. This version does
|
|
nothing and is intended to be implemented by subclasses.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}[Handler]{handle}{record}
|
|
Conditionally emits the specified logging record, depending on
|
|
filters which may have been added to the handler. Wraps the actual
|
|
emission of the record with acquisition/release of the I/O thread
|
|
lock.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}[Handler]{handleError}{record}
|
|
This method should be called from handlers when an exception is
|
|
encountered during an \method{emit()} call. By default it does nothing,
|
|
which means that exceptions get silently ignored. This is what is
|
|
mostly wanted for a logging system - most users will not care
|
|
about errors in the logging system, they are more interested in
|
|
application errors. You could, however, replace this with a custom
|
|
handler if you wish. The specified record is the one which was being
|
|
processed when the exception occurred.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}[Handler]{format}{record}
|
|
Do formatting for a record - if a formatter is set, use it.
|
|
Otherwise, use the default formatter for the module.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}[Handler]{emit}{record}
|
|
Do whatever it takes to actually log the specified logging record.
|
|
This version is intended to be implemented by subclasses and so
|
|
raises a \exception{NotImplementedError}.
|
|
\end{methoddesc}
|
|
|
|
\subsubsection{StreamHandler}
|
|
|
|
The \class{StreamHandler} class, located in the core \module{logging}
|
|
package, sends logging output to streams such as \var{sys.stdout},
|
|
\var{sys.stderr} or any file-like object (or, more precisely, any
|
|
object which supports \method{write()} and \method{flush()} methods).
|
|
|
|
\begin{classdesc}{StreamHandler}{\optional{strm}}
|
|
Returns a new instance of the \class{StreamHandler} class. If \var{strm} is
|
|
specified, the instance will use it for logging output; otherwise,
|
|
\var{sys.stderr} will be used.
|
|
\end{classdesc}
|
|
|
|
\begin{methoddesc}{emit}{record}
|
|
If a formatter is specified, it is used to format the record.
|
|
The record is then written to the stream with a trailing newline.
|
|
If exception information is present, it is formatted using
|
|
\function{traceback.print_exception()} and appended to the stream.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}{flush}{}
|
|
Flushes the stream by calling its \method{flush()} method. Note that
|
|
the \method{close()} method is inherited from \class{Handler} and
|
|
so does nothing, so an explicit \method{flush()} call may be needed
|
|
at times.
|
|
\end{methoddesc}
|
|
|
|
\subsubsection{FileHandler}
|
|
|
|
The \class{FileHandler} class, located in the core \module{logging}
|
|
package, sends logging output to a disk file. It inherits the output
|
|
functionality from \class{StreamHandler}.
|
|
|
|
\begin{classdesc}{FileHandler}{filename\optional{, mode\optional{, encoding}}}
|
|
Returns a new instance of the \class{FileHandler} class. The specified
|
|
file is opened and used as the stream for logging. If \var{mode} is
|
|
not specified, \constant{'a'} is used. If \var{encoding} is not \var{None},
|
|
it is used to open the file with that encoding. By default, the file grows
|
|
indefinitely.
|
|
\end{classdesc}
|
|
|
|
\begin{methoddesc}{close}{}
|
|
Closes the file.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}{emit}{record}
|
|
Outputs the record to the file.
|
|
\end{methoddesc}
|
|
|
|
\subsubsection{WatchedFileHandler}
|
|
|
|
\versionadded{2.6}
|
|
The \class{WatchedFileHandler} class, located in the \module{logging.handlers}
|
|
module, is a \class{FileHandler} which watches the file it is logging to.
|
|
If the file changes, it is closed and reopened using the file name.
|
|
|
|
A file change can happen because of usage of programs such as \var{newsyslog}
|
|
and \var{logrotate} which perform log file rotation. This handler, intended
|
|
for use under Unix/Linux, watches the file to see if it has changed since the
|
|
last emit. (A file is deemed to have changed if its device or inode have
|
|
changed.) If the file has changed, the old file stream is closed, and the file
|
|
opened to get a new stream.
|
|
|
|
This handler is not appropriate for use under Windows, because under Windows
|
|
open log files cannot be moved or renamed - logging opens the files with
|
|
exclusive locks - and so there is no need for such a handler. Furthermore,
|
|
\var{ST_INO} is not supported under Windows; \function{stat()} always returns
|
|
zero for this value.
|
|
|
|
\begin{classdesc}{WatchedFileHandler}{filename\optional{,mode\optional{,
|
|
encoding}}}
|
|
Returns a new instance of the \class{WatchedFileHandler} class. The specified
|
|
file is opened and used as the stream for logging. If \var{mode} is
|
|
not specified, \constant{'a'} is used. If \var{encoding} is not \var{None},
|
|
it is used to open the file with that encoding. By default, the file grows
|
|
indefinitely.
|
|
\end{classdesc}
|
|
|
|
\begin{methoddesc}{emit}{record}
|
|
Outputs the record to the file, but first checks to see if the file has
|
|
changed. If it has, the existing stream is flushed and closed and the file
|
|
opened again, before outputting the record to the file.
|
|
\end{methoddesc}
|
|
|
|
\subsubsection{RotatingFileHandler}
|
|
|
|
The \class{RotatingFileHandler} class, located in the \module{logging.handlers}
|
|
module, supports rotation of disk log files.
|
|
|
|
\begin{classdesc}{RotatingFileHandler}{filename\optional{, mode\optional{,
|
|
maxBytes\optional{, backupCount}}}}
|
|
Returns a new instance of the \class{RotatingFileHandler} class. The
|
|
specified file is opened and used as the stream for logging. If
|
|
\var{mode} is not specified, \code{'a'} is used. By default, the
|
|
file grows indefinitely.
|
|
|
|
You can use the \var{maxBytes} and
|
|
\var{backupCount} values to allow the file to \dfn{rollover} at a
|
|
predetermined size. When the size is about to be exceeded, the file is
|
|
closed and a new file is silently opened for output. Rollover occurs
|
|
whenever the current log file is nearly \var{maxBytes} in length; if
|
|
\var{maxBytes} is zero, rollover never occurs. If \var{backupCount}
|
|
is non-zero, the system will save old log files by appending the
|
|
extensions ".1", ".2" etc., to the filename. For example, with
|
|
a \var{backupCount} of 5 and a base file name of
|
|
\file{app.log}, you would get \file{app.log},
|
|
\file{app.log.1}, \file{app.log.2}, up to \file{app.log.5}. The file being
|
|
written to is always \file{app.log}. When this file is filled, it is
|
|
closed and renamed to \file{app.log.1}, and if files \file{app.log.1},
|
|
\file{app.log.2}, etc. exist, then they are renamed to \file{app.log.2},
|
|
\file{app.log.3} etc. respectively.
|
|
\end{classdesc}
|
|
|
|
\begin{methoddesc}{doRollover}{}
|
|
Does a rollover, as described above.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}{emit}{record}
|
|
Outputs the record to the file, catering for rollover as described previously.
|
|
\end{methoddesc}
|
|
|
|
\subsubsection{TimedRotatingFileHandler}
|
|
|
|
The \class{TimedRotatingFileHandler} class, located in the
|
|
\module{logging.handlers} module, supports rotation of disk log files
|
|
at certain timed intervals.
|
|
|
|
\begin{classdesc}{TimedRotatingFileHandler}{filename
|
|
\optional{,when
|
|
\optional{,interval
|
|
\optional{,backupCount}}}}
|
|
|
|
Returns a new instance of the \class{TimedRotatingFileHandler} class. The
|
|
specified file is opened and used as the stream for logging. On rotating
|
|
it also sets the filename suffix. Rotating happens based on the product
|
|
of \var{when} and \var{interval}.
|
|
|
|
You can use the \var{when} to specify the type of \var{interval}. The
|
|
list of possible values is, note that they are not case sensitive:
|
|
|
|
\begin{tableii}{l|l}{}{Value}{Type of interval}
|
|
\lineii{S}{Seconds}
|
|
\lineii{M}{Minutes}
|
|
\lineii{H}{Hours}
|
|
\lineii{D}{Days}
|
|
\lineii{W}{Week day (0=Monday)}
|
|
\lineii{midnight}{Roll over at midnight}
|
|
\end{tableii}
|
|
|
|
If \var{backupCount} is non-zero, the system will save old log files by
|
|
appending extensions to the filename. The extensions are date-and-time
|
|
based, using the strftime format \code{\%Y-\%m-\%d_\%H-\%M-\%S} or a leading
|
|
portion thereof, depending on the rollover interval. At most \var{backupCount}
|
|
files will be kept, and if more would be created when rollover occurs, the
|
|
oldest one is deleted.
|
|
\end{classdesc}
|
|
|
|
\begin{methoddesc}{doRollover}{}
|
|
Does a rollover, as described above.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}{emit}{record}
|
|
Outputs the record to the file, catering for rollover as described
|
|
above.
|
|
\end{methoddesc}
|
|
|
|
\subsubsection{SocketHandler}
|
|
|
|
The \class{SocketHandler} class, located in the
|
|
\module{logging.handlers} module, sends logging output to a network
|
|
socket. The base class uses a TCP socket.
|
|
|
|
\begin{classdesc}{SocketHandler}{host, port}
|
|
Returns a new instance of the \class{SocketHandler} class intended to
|
|
communicate with a remote machine whose address is given by \var{host}
|
|
and \var{port}.
|
|
\end{classdesc}
|
|
|
|
\begin{methoddesc}{close}{}
|
|
Closes the socket.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}{emit}{}
|
|
Pickles the record's attribute dictionary and writes it to the socket in
|
|
binary format. If there is an error with the socket, silently drops the
|
|
packet. If the connection was previously lost, re-establishes the connection.
|
|
To unpickle the record at the receiving end into a \class{LogRecord}, use the
|
|
\function{makeLogRecord()} function.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}{handleError}{}
|
|
Handles an error which has occurred during \method{emit()}. The
|
|
most likely cause is a lost connection. Closes the socket so that
|
|
we can retry on the next event.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}{makeSocket}{}
|
|
This is a factory method which allows subclasses to define the precise
|
|
type of socket they want. The default implementation creates a TCP
|
|
socket (\constant{socket.SOCK_STREAM}).
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}{makePickle}{record}
|
|
Pickles the record's attribute dictionary in binary format with a length
|
|
prefix, and returns it ready for transmission across the socket.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}{send}{packet}
|
|
Send a pickled string \var{packet} to the socket. This function allows
|
|
for partial sends which can happen when the network is busy.
|
|
\end{methoddesc}
|
|
|
|
\subsubsection{DatagramHandler}
|
|
|
|
The \class{DatagramHandler} class, located in the
|
|
\module{logging.handlers} module, inherits from \class{SocketHandler}
|
|
to support sending logging messages over UDP sockets.
|
|
|
|
\begin{classdesc}{DatagramHandler}{host, port}
|
|
Returns a new instance of the \class{DatagramHandler} class intended to
|
|
communicate with a remote machine whose address is given by \var{host}
|
|
and \var{port}.
|
|
\end{classdesc}
|
|
|
|
\begin{methoddesc}{emit}{}
|
|
Pickles the record's attribute dictionary and writes it to the socket in
|
|
binary format. If there is an error with the socket, silently drops the
|
|
packet.
|
|
To unpickle the record at the receiving end into a \class{LogRecord}, use the
|
|
\function{makeLogRecord()} function.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}{makeSocket}{}
|
|
The factory method of \class{SocketHandler} is here overridden to create
|
|
a UDP socket (\constant{socket.SOCK_DGRAM}).
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}{send}{s}
|
|
Send a pickled string to a socket.
|
|
\end{methoddesc}
|
|
|
|
\subsubsection{SysLogHandler}
|
|
|
|
The \class{SysLogHandler} class, located in the
|
|
\module{logging.handlers} module, supports sending logging messages to
|
|
a remote or local \UNIX{} syslog.
|
|
|
|
\begin{classdesc}{SysLogHandler}{\optional{address\optional{, facility}}}
|
|
Returns a new instance of the \class{SysLogHandler} class intended to
|
|
communicate with a remote \UNIX{} machine whose address is given by
|
|
\var{address} in the form of a \code{(\var{host}, \var{port})}
|
|
tuple. If \var{address} is not specified, \code{('localhost', 514)} is
|
|
used. The address is used to open a UDP socket. An alternative to providing
|
|
a \code{(\var{host}, \var{port})} tuple is providing an address as a string,
|
|
for example "/dev/log". In this case, a Unix domain socket is used to send
|
|
the message to the syslog. If \var{facility} is not specified,
|
|
\constant{LOG_USER} is used.
|
|
\end{classdesc}
|
|
|
|
\begin{methoddesc}{close}{}
|
|
Closes the socket to the remote host.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}{emit}{record}
|
|
The record is formatted, and then sent to the syslog server. If
|
|
exception information is present, it is \emph{not} sent to the server.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}{encodePriority}{facility, priority}
|
|
Encodes the facility and priority into an integer. You can pass in strings
|
|
or integers - if strings are passed, internal mapping dictionaries are used
|
|
to convert them to integers.
|
|
\end{methoddesc}
|
|
|
|
\subsubsection{NTEventLogHandler}
|
|
|
|
The \class{NTEventLogHandler} class, located in the
|
|
\module{logging.handlers} module, supports sending logging messages to
|
|
a local Windows NT, Windows 2000 or Windows XP event log. Before you
|
|
can use it, you need Mark Hammond's Win32 extensions for Python
|
|
installed.
|
|
|
|
\begin{classdesc}{NTEventLogHandler}{appname\optional{,
|
|
dllname\optional{, logtype}}}
|
|
Returns a new instance of the \class{NTEventLogHandler} class. The
|
|
\var{appname} is used to define the application name as it appears in the
|
|
event log. An appropriate registry entry is created using this name.
|
|
The \var{dllname} should give the fully qualified pathname of a .dll or .exe
|
|
which contains message definitions to hold in the log (if not specified,
|
|
\code{'win32service.pyd'} is used - this is installed with the Win32
|
|
extensions and contains some basic placeholder message definitions.
|
|
Note that use of these placeholders will make your event logs big, as the
|
|
entire message source is held in the log. If you want slimmer logs, you have
|
|
to pass in the name of your own .dll or .exe which contains the message
|
|
definitions you want to use in the event log). The \var{logtype} is one of
|
|
\code{'Application'}, \code{'System'} or \code{'Security'}, and
|
|
defaults to \code{'Application'}.
|
|
\end{classdesc}
|
|
|
|
\begin{methoddesc}{close}{}
|
|
At this point, you can remove the application name from the registry as a
|
|
source of event log entries. However, if you do this, you will not be able
|
|
to see the events as you intended in the Event Log Viewer - it needs to be
|
|
able to access the registry to get the .dll name. The current version does
|
|
not do this (in fact it doesn't do anything).
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}{emit}{record}
|
|
Determines the message ID, event category and event type, and then logs the
|
|
message in the NT event log.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}{getEventCategory}{record}
|
|
Returns the event category for the record. Override this if you
|
|
want to specify your own categories. This version returns 0.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}{getEventType}{record}
|
|
Returns the event type for the record. Override this if you want
|
|
to specify your own types. This version does a mapping using the
|
|
handler's typemap attribute, which is set up in \method{__init__()}
|
|
to a dictionary which contains mappings for \constant{DEBUG},
|
|
\constant{INFO}, \constant{WARNING}, \constant{ERROR} and
|
|
\constant{CRITICAL}. If you are using your own levels, you will either need
|
|
to override this method or place a suitable dictionary in the
|
|
handler's \var{typemap} attribute.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}{getMessageID}{record}
|
|
Returns the message ID for the record. If you are using your
|
|
own messages, you could do this by having the \var{msg} passed to the
|
|
logger being an ID rather than a format string. Then, in here,
|
|
you could use a dictionary lookup to get the message ID. This
|
|
version returns 1, which is the base message ID in
|
|
\file{win32service.pyd}.
|
|
\end{methoddesc}
|
|
|
|
\subsubsection{SMTPHandler}
|
|
|
|
The \class{SMTPHandler} class, located in the
|
|
\module{logging.handlers} module, supports sending logging messages to
|
|
an email address via SMTP.
|
|
|
|
\begin{classdesc}{SMTPHandler}{mailhost, fromaddr, toaddrs, subject\optional{,
|
|
credentials}}
|
|
Returns a new instance of the \class{SMTPHandler} class. The
|
|
instance is initialized with the from and to addresses and subject
|
|
line of the email. The \var{toaddrs} should be a list of strings. To specify a
|
|
non-standard SMTP port, use the (host, port) tuple format for the
|
|
\var{mailhost} argument. If you use a string, the standard SMTP port
|
|
is used. If your SMTP server requires authentication, you can specify a
|
|
(username, password) tuple for the \var{credentials} argument.
|
|
\versionchanged[\var{credentials} was added]{2.6}
|
|
\end{classdesc}
|
|
|
|
\begin{methoddesc}{emit}{record}
|
|
Formats the record and sends it to the specified addressees.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}{getSubject}{record}
|
|
If you want to specify a subject line which is record-dependent,
|
|
override this method.
|
|
\end{methoddesc}
|
|
|
|
\subsubsection{MemoryHandler}
|
|
|
|
The \class{MemoryHandler} class, located in the
|
|
\module{logging.handlers} module, supports buffering of logging
|
|
records in memory, periodically flushing them to a \dfn{target}
|
|
handler. Flushing occurs whenever the buffer is full, or when an event
|
|
of a certain severity or greater is seen.
|
|
|
|
\class{MemoryHandler} is a subclass of the more general
|
|
\class{BufferingHandler}, which is an abstract class. This buffers logging
|
|
records in memory. Whenever each record is added to the buffer, a
|
|
check is made by calling \method{shouldFlush()} to see if the buffer
|
|
should be flushed. If it should, then \method{flush()} is expected to
|
|
do the needful.
|
|
|
|
\begin{classdesc}{BufferingHandler}{capacity}
|
|
Initializes the handler with a buffer of the specified capacity.
|
|
\end{classdesc}
|
|
|
|
\begin{methoddesc}{emit}{record}
|
|
Appends the record to the buffer. If \method{shouldFlush()} returns true,
|
|
calls \method{flush()} to process the buffer.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}{flush}{}
|
|
You can override this to implement custom flushing behavior. This version
|
|
just zaps the buffer to empty.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}{shouldFlush}{record}
|
|
Returns true if the buffer is up to capacity. This method can be
|
|
overridden to implement custom flushing strategies.
|
|
\end{methoddesc}
|
|
|
|
\begin{classdesc}{MemoryHandler}{capacity\optional{, flushLevel
|
|
\optional{, target}}}
|
|
Returns a new instance of the \class{MemoryHandler} class. The
|
|
instance is initialized with a buffer size of \var{capacity}. If
|
|
\var{flushLevel} is not specified, \constant{ERROR} is used. If no
|
|
\var{target} is specified, the target will need to be set using
|
|
\method{setTarget()} before this handler does anything useful.
|
|
\end{classdesc}
|
|
|
|
\begin{methoddesc}{close}{}
|
|
Calls \method{flush()}, sets the target to \constant{None} and
|
|
clears the buffer.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}{flush}{}
|
|
For a \class{MemoryHandler}, flushing means just sending the buffered
|
|
records to the target, if there is one. Override if you want
|
|
different behavior.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}{setTarget}{target}
|
|
Sets the target handler for this handler.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}{shouldFlush}{record}
|
|
Checks for buffer full or a record at the \var{flushLevel} or higher.
|
|
\end{methoddesc}
|
|
|
|
\subsubsection{HTTPHandler}
|
|
|
|
The \class{HTTPHandler} class, located in the
|
|
\module{logging.handlers} module, supports sending logging messages to
|
|
a Web server, using either \samp{GET} or \samp{POST} semantics.
|
|
|
|
\begin{classdesc}{HTTPHandler}{host, url\optional{, method}}
|
|
Returns a new instance of the \class{HTTPHandler} class. The
|
|
instance is initialized with a host address, url and HTTP method.
|
|
The \var{host} can be of the form \code{host:port}, should you need to
|
|
use a specific port number. If no \var{method} is specified, \samp{GET}
|
|
is used.
|
|
\end{classdesc}
|
|
|
|
\begin{methoddesc}{emit}{record}
|
|
Sends the record to the Web server as an URL-encoded dictionary.
|
|
\end{methoddesc}
|
|
|
|
\subsection{Formatter Objects}
|
|
|
|
\class{Formatter}s have the following attributes and methods. They are
|
|
responsible for converting a \class{LogRecord} to (usually) a string
|
|
which can be interpreted by either a human or an external system. The
|
|
base
|
|
\class{Formatter} allows a formatting string to be specified. If none is
|
|
supplied, the default value of \code{'\%(message)s'} is used.
|
|
|
|
A Formatter can be initialized with a format string which makes use of
|
|
knowledge of the \class{LogRecord} attributes - such as the default value
|
|
mentioned above making use of the fact that the user's message and
|
|
arguments are pre-formatted into a \class{LogRecord}'s \var{message}
|
|
attribute. This format string contains standard python \%-style
|
|
mapping keys. See section \ref{typesseq-strings}, ``String Formatting
|
|
Operations,'' for more information on string formatting.
|
|
|
|
Currently, the useful mapping keys in a \class{LogRecord} are:
|
|
|
|
\begin{tableii}{l|l}{code}{Format}{Description}
|
|
\lineii{\%(name)s} {Name of the logger (logging channel).}
|
|
\lineii{\%(levelno)s} {Numeric logging level for the message
|
|
(\constant{DEBUG}, \constant{INFO},
|
|
\constant{WARNING}, \constant{ERROR},
|
|
\constant{CRITICAL}).}
|
|
\lineii{\%(levelname)s}{Text logging level for the message
|
|
(\code{'DEBUG'}, \code{'INFO'},
|
|
\code{'WARNING'}, \code{'ERROR'},
|
|
\code{'CRITICAL'}).}
|
|
\lineii{\%(pathname)s} {Full pathname of the source file where the logging
|
|
call was issued (if available).}
|
|
\lineii{\%(filename)s} {Filename portion of pathname.}
|
|
\lineii{\%(module)s} {Module (name portion of filename).}
|
|
\lineii{\%(funcName)s} {Name of function containing the logging call.}
|
|
\lineii{\%(lineno)d} {Source line number where the logging call was issued
|
|
(if available).}
|
|
\lineii{\%(created)f} {Time when the \class{LogRecord} was created (as
|
|
returned by \function{time.time()}).}
|
|
\lineii{\%(relativeCreated)d} {Time in milliseconds when the LogRecord was
|
|
created, relative to the time the logging module was
|
|
loaded.}
|
|
\lineii{\%(asctime)s} {Human-readable time when the \class{LogRecord}
|
|
was created. By default this is of the form
|
|
``2003-07-08 16:49:45,896'' (the numbers after the
|
|
comma are millisecond portion of the time).}
|
|
\lineii{\%(msecs)d} {Millisecond portion of the time when the
|
|
\class{LogRecord} was created.}
|
|
\lineii{\%(thread)d} {Thread ID (if available).}
|
|
\lineii{\%(threadName)s} {Thread name (if available).}
|
|
\lineii{\%(process)d} {Process ID (if available).}
|
|
\lineii{\%(message)s} {The logged message, computed as \code{msg \% args}.}
|
|
\end{tableii}
|
|
|
|
\versionchanged[\var{funcName} was added]{2.5}
|
|
|
|
\begin{classdesc}{Formatter}{\optional{fmt\optional{, datefmt}}}
|
|
Returns a new instance of the \class{Formatter} class. The
|
|
instance is initialized with a format string for the message as a whole,
|
|
as well as a format string for the date/time portion of a message. If
|
|
no \var{fmt} is specified, \code{'\%(message)s'} is used. If no \var{datefmt}
|
|
is specified, the ISO8601 date format is used.
|
|
\end{classdesc}
|
|
|
|
\begin{methoddesc}{format}{record}
|
|
The record's attribute dictionary is used as the operand to a
|
|
string formatting operation. Returns the resulting string.
|
|
Before formatting the dictionary, a couple of preparatory steps
|
|
are carried out. The \var{message} attribute of the record is computed
|
|
using \var{msg} \% \var{args}. If the formatting string contains
|
|
\code{'(asctime)'}, \method{formatTime()} is called to format the
|
|
event time. If there is exception information, it is formatted using
|
|
\method{formatException()} and appended to the message.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}{formatTime}{record\optional{, datefmt}}
|
|
This method should be called from \method{format()} by a formatter which
|
|
wants to make use of a formatted time. This method can be overridden
|
|
in formatters to provide for any specific requirement, but the
|
|
basic behavior is as follows: if \var{datefmt} (a string) is specified,
|
|
it is used with \function{time.strftime()} to format the creation time of the
|
|
record. Otherwise, the ISO8601 format is used. The resulting
|
|
string is returned.
|
|
\end{methoddesc}
|
|
|
|
\begin{methoddesc}{formatException}{exc_info}
|
|
Formats the specified exception information (a standard exception tuple
|
|
as returned by \function{sys.exc_info()}) as a string. This default
|
|
implementation just uses \function{traceback.print_exception()}.
|
|
The resulting string is returned.
|
|
\end{methoddesc}
|
|
|
|
\subsection{Filter Objects}
|
|
|
|
\class{Filter}s can be used by \class{Handler}s and \class{Logger}s for
|
|
more sophisticated filtering than is provided by levels. The base filter
|
|
class only allows events which are below a certain point in the logger
|
|
hierarchy. For example, a filter initialized with "A.B" will allow events
|
|
logged by loggers "A.B", "A.B.C", "A.B.C.D", "A.B.D" etc. but not "A.BB",
|
|
"B.A.B" etc. If initialized with the empty string, all events are passed.
|
|
|
|
\begin{classdesc}{Filter}{\optional{name}}
|
|
Returns an instance of the \class{Filter} class. If \var{name} is specified,
|
|
it names a logger which, together with its children, will have its events
|
|
allowed through the filter. If no name is specified, allows every event.
|
|
\end{classdesc}
|
|
|
|
\begin{methoddesc}{filter}{record}
|
|
Is the specified record to be logged? Returns zero for no, nonzero for
|
|
yes. If deemed appropriate, the record may be modified in-place by this
|
|
method.
|
|
\end{methoddesc}
|
|
|
|
\subsection{LogRecord Objects}
|
|
|
|
\class{LogRecord} instances are created every time something is logged. They
|
|
contain all the information pertinent to the event being logged. The
|
|
main information passed in is in msg and args, which are combined
|
|
using msg \% args to create the message field of the record. The record
|
|
also includes information such as when the record was created, the
|
|
source line where the logging call was made, and any exception
|
|
information to be logged.
|
|
|
|
\begin{classdesc}{LogRecord}{name, lvl, pathname, lineno, msg, args,
|
|
exc_info \optional{, func}}
|
|
Returns an instance of \class{LogRecord} initialized with interesting
|
|
information. The \var{name} is the logger name; \var{lvl} is the
|
|
numeric level; \var{pathname} is the absolute pathname of the source
|
|
file in which the logging call was made; \var{lineno} is the line
|
|
number in that file where the logging call is found; \var{msg} is the
|
|
user-supplied message (a format string); \var{args} is the tuple
|
|
which, together with \var{msg}, makes up the user message; and
|
|
\var{exc_info} is the exception tuple obtained by calling
|
|
\function{sys.exc_info() }(or \constant{None}, if no exception information
|
|
is available). The \var{func} is the name of the function from which the
|
|
logging call was made. If not specified, it defaults to \code{None}.
|
|
\versionchanged[\var{func} was added]{2.5}
|
|
\end{classdesc}
|
|
|
|
\begin{methoddesc}{getMessage}{}
|
|
Returns the message for this \class{LogRecord} instance after merging any
|
|
user-supplied arguments with the message.
|
|
\end{methoddesc}
|
|
|
|
\subsection{Thread Safety}
|
|
|
|
The logging module is intended to be thread-safe without any special work
|
|
needing to be done by its clients. It achieves this though using threading
|
|
locks; there is one lock to serialize access to the module's shared data,
|
|
and each handler also creates a lock to serialize access to its underlying
|
|
I/O.
|
|
|
|
\subsection{Configuration}
|
|
|
|
|
|
\subsubsection{Configuration functions%
|
|
\label{logging-config-api}}
|
|
|
|
The following functions configure the logging module. They are located in the
|
|
\module{logging.config} module. Their use is optional --- you can configure
|
|
the logging module using these functions or by making calls to the
|
|
main API (defined in \module{logging} itself) and defining handlers
|
|
which are declared either in \module{logging} or
|
|
\module{logging.handlers}.
|
|
|
|
\begin{funcdesc}{fileConfig}{fname\optional{, defaults}}
|
|
Reads the logging configuration from a ConfigParser-format file named
|
|
\var{fname}. This function can be called several times from an application,
|
|
allowing an end user the ability to select from various pre-canned
|
|
configurations (if the developer provides a mechanism to present the
|
|
choices and load the chosen configuration). Defaults to be passed to
|
|
ConfigParser can be specified in the \var{defaults} argument.
|
|
\end{funcdesc}
|
|
|
|
\begin{funcdesc}{listen}{\optional{port}}
|
|
Starts up a socket server on the specified port, and listens for new
|
|
configurations. If no port is specified, the module's default
|
|
\constant{DEFAULT_LOGGING_CONFIG_PORT} is used. Logging configurations
|
|
will be sent as a file suitable for processing by \function{fileConfig()}.
|
|
Returns a \class{Thread} instance on which you can call \method{start()}
|
|
to start the server, and which you can \method{join()} when appropriate.
|
|
To stop the server, call \function{stopListening()}. To send a configuration
|
|
to the socket, read in the configuration file and send it to the socket
|
|
as a string of bytes preceded by a four-byte length packed in binary using
|
|
struct.\code{pack('>L', n)}.
|
|
\end{funcdesc}
|
|
|
|
\begin{funcdesc}{stopListening}{}
|
|
Stops the listening server which was created with a call to
|
|
\function{listen()}. This is typically called before calling \method{join()}
|
|
on the return value from \function{listen()}.
|
|
\end{funcdesc}
|
|
|
|
\subsubsection{Configuration file format%
|
|
\label{logging-config-fileformat}}
|
|
|
|
The configuration file format understood by \function{fileConfig()} is
|
|
based on ConfigParser functionality. The file must contain sections
|
|
called \code{[loggers]}, \code{[handlers]} and \code{[formatters]}
|
|
which identify by name the entities of each type which are defined in
|
|
the file. For each such entity, there is a separate section which
|
|
identified how that entity is configured. Thus, for a logger named
|
|
\code{log01} in the \code{[loggers]} section, the relevant
|
|
configuration details are held in a section
|
|
\code{[logger_log01]}. Similarly, a handler called \code{hand01} in
|
|
the \code{[handlers]} section will have its configuration held in a
|
|
section called \code{[handler_hand01]}, while a formatter called
|
|
\code{form01} in the \code{[formatters]} section will have its
|
|
configuration specified in a section called
|
|
\code{[formatter_form01]}. The root logger configuration must be
|
|
specified in a section called \code{[logger_root]}.
|
|
|
|
Examples of these sections in the file are given below.
|
|
|
|
\begin{verbatim}
|
|
[loggers]
|
|
keys=root,log02,log03,log04,log05,log06,log07
|
|
|
|
[handlers]
|
|
keys=hand01,hand02,hand03,hand04,hand05,hand06,hand07,hand08,hand09
|
|
|
|
[formatters]
|
|
keys=form01,form02,form03,form04,form05,form06,form07,form08,form09
|
|
\end{verbatim}
|
|
|
|
The root logger must specify a level and a list of handlers. An
|
|
example of a root logger section is given below.
|
|
|
|
\begin{verbatim}
|
|
[logger_root]
|
|
level=NOTSET
|
|
handlers=hand01
|
|
\end{verbatim}
|
|
|
|
The \code{level} entry can be one of \code{DEBUG, INFO, WARNING,
|
|
ERROR, CRITICAL} or \code{NOTSET}. For the root logger only,
|
|
\code{NOTSET} means that all messages will be logged. Level values are
|
|
\function{eval()}uated in the context of the \code{logging} package's
|
|
namespace.
|
|
|
|
The \code{handlers} entry is a comma-separated list of handler names,
|
|
which must appear in the \code{[handlers]} section. These names must
|
|
appear in the \code{[handlers]} section and have corresponding
|
|
sections in the configuration file.
|
|
|
|
For loggers other than the root logger, some additional information is
|
|
required. This is illustrated by the following example.
|
|
|
|
\begin{verbatim}
|
|
[logger_parser]
|
|
level=DEBUG
|
|
handlers=hand01
|
|
propagate=1
|
|
qualname=compiler.parser
|
|
\end{verbatim}
|
|
|
|
The \code{level} and \code{handlers} entries are interpreted as for
|
|
the root logger, except that if a non-root logger's level is specified
|
|
as \code{NOTSET}, the system consults loggers higher up the hierarchy
|
|
to determine the effective level of the logger. The \code{propagate}
|
|
entry is set to 1 to indicate that messages must propagate to handlers
|
|
higher up the logger hierarchy from this logger, or 0 to indicate that
|
|
messages are \strong{not} propagated to handlers up the hierarchy. The
|
|
\code{qualname} entry is the hierarchical channel name of the logger,
|
|
that is to say the name used by the application to get the logger.
|
|
|
|
Sections which specify handler configuration are exemplified by the
|
|
following.
|
|
|
|
\begin{verbatim}
|
|
[handler_hand01]
|
|
class=StreamHandler
|
|
level=NOTSET
|
|
formatter=form01
|
|
args=(sys.stdout,)
|
|
\end{verbatim}
|
|
|
|
The \code{class} entry indicates the handler's class (as determined by
|
|
\function{eval()} in the \code{logging} package's namespace). The
|
|
\code{level} is interpreted as for loggers, and \code{NOTSET} is taken
|
|
to mean "log everything".
|
|
|
|
The \code{formatter} entry indicates the key name of the formatter for
|
|
this handler. If blank, a default formatter
|
|
(\code{logging._defaultFormatter}) is used. If a name is specified, it
|
|
must appear in the \code{[formatters]} section and have a
|
|
corresponding section in the configuration file.
|
|
|
|
The \code{args} entry, when \function{eval()}uated in the context of
|
|
the \code{logging} package's namespace, is the list of arguments to
|
|
the constructor for the handler class. Refer to the constructors for
|
|
the relevant handlers, or to the examples below, to see how typical
|
|
entries are constructed.
|
|
|
|
\begin{verbatim}
|
|
[handler_hand02]
|
|
class=FileHandler
|
|
level=DEBUG
|
|
formatter=form02
|
|
args=('python.log', 'w')
|
|
|
|
[handler_hand03]
|
|
class=handlers.SocketHandler
|
|
level=INFO
|
|
formatter=form03
|
|
args=('localhost', handlers.DEFAULT_TCP_LOGGING_PORT)
|
|
|
|
[handler_hand04]
|
|
class=handlers.DatagramHandler
|
|
level=WARN
|
|
formatter=form04
|
|
args=('localhost', handlers.DEFAULT_UDP_LOGGING_PORT)
|
|
|
|
[handler_hand05]
|
|
class=handlers.SysLogHandler
|
|
level=ERROR
|
|
formatter=form05
|
|
args=(('localhost', handlers.SYSLOG_UDP_PORT), handlers.SysLogHandler.LOG_USER)
|
|
|
|
[handler_hand06]
|
|
class=handlers.NTEventLogHandler
|
|
level=CRITICAL
|
|
formatter=form06
|
|
args=('Python Application', '', 'Application')
|
|
|
|
[handler_hand07]
|
|
class=handlers.SMTPHandler
|
|
level=WARN
|
|
formatter=form07
|
|
args=('localhost', 'from@abc', ['user1@abc', 'user2@xyz'], 'Logger Subject')
|
|
|
|
[handler_hand08]
|
|
class=handlers.MemoryHandler
|
|
level=NOTSET
|
|
formatter=form08
|
|
target=
|
|
args=(10, ERROR)
|
|
|
|
[handler_hand09]
|
|
class=handlers.HTTPHandler
|
|
level=NOTSET
|
|
formatter=form09
|
|
args=('localhost:9022', '/log', 'GET')
|
|
\end{verbatim}
|
|
|
|
Sections which specify formatter configuration are typified by the following.
|
|
|
|
\begin{verbatim}
|
|
[formatter_form01]
|
|
format=F1 %(asctime)s %(levelname)s %(message)s
|
|
datefmt=
|
|
class=logging.Formatter
|
|
\end{verbatim}
|
|
|
|
The \code{format} entry is the overall format string, and the
|
|
\code{datefmt} entry is the \function{strftime()}-compatible date/time format
|
|
string. If empty, the package substitutes ISO8601 format date/times, which
|
|
is almost equivalent to specifying the date format string "%Y-%m-%d %H:%M:%S".
|
|
The ISO8601 format also specifies milliseconds, which are appended to the
|
|
result of using the above format string, with a comma separator. An example
|
|
time in ISO8601 format is \code{2003-01-23 00:29:50,411}.
|
|
|
|
The \code{class} entry is optional. It indicates the name of the
|
|
formatter's class (as a dotted module and class name.) This option is
|
|
useful for instantiating a \class{Formatter} subclass. Subclasses of
|
|
\class{Formatter} can present exception tracebacks in an expanded or
|
|
condensed format.
|